Question 14.6: A vapor compression heat pump consisting of an evaporator, c......

A vapor compression heat pump consisting of an evaporator, compressor, condenser, and expansion valve is operating in the cooling mode with a COP of 3.2. The compressor input power is 12 kW. Determine the rate of useful heat production in the evaporator and the rate of heat rejection in the condenser.

Step-by-Step
The 'Blue Check Mark' means that this solution was answered by an expert.
Learn more on how do we answer questions.

1. Rate of useful heat production in the evaporator (in cooling mode)

Q_{\mathrm{ev}}=P_{\mathrm{cr}}/\mathrm{COP}=12/3.2=3.75\,{\mathrm{kW}}

2. Rate of heat rejection in the condenser

Q_{\mathrm{c}}=Q_{\mathrm{ev}}+P_{\mathrm{cr}}=3.75+12=15,75\,{\mathrm{kW}}