Question 11.10: The R Value of a Typical Wall Goal Calculate the R value of ...
The R Value of a Typical Wall
Goal Calculate the R value of a wall consisting of several layers of insulating material.
Problem Calculate the total R value for a wall constructed as shown in Figure 11.8a. Starting outside the house (to the left in the figure) and moving inward, the wall consists of 4.0 \mathrm{in}. brick, 0.50 \mathrm{in}. sheathing, an air space 3.5 \mathrm{in}. thick, and 0.50 in. drywall.
Strategy Add all the R values together, remembering the stagnant air layers inside and outside the house.

Learn more on how we answer questions.
Refer to Table 11.4, and sum. All quantities are in units of \mathrm{ft}^{2} \cdot{ }^{\circ} \mathrm{F} \cdot \mathrm{h} / \mathrm{Btu}.
\begin{aligned} & R_{\text {total }}=R_{\text {outside air layer }}+R_{\text {brick }}+R_{\text {sheath }}+R_{\text {air space }} \\ & \quad+R_{\text {drywall }}+R_{\text {inside air layer }}=(0.17+4.00+1.32+1.01 \\ & \quad+0.45+0.17) \mathrm{ft}^{2} \cdot{ }^{\circ} \mathrm{F} \cdot \mathrm{h} / \mathrm{Btu} \\ & R_{\text {total }}=7.12 \mathrm{ft}^{2} \cdot{ }^{\circ} \mathrm{F} \cdot \mathrm{h} / \mathrm{Btu} \end{aligned}
TABLE 11.4
R Values for Some Common Building Materials
Material | R value (ft2 · °F · h/Btu) |
Hardwood siding (1.0 in. thick) | 0.91 |
Wood shingles (lapped) | 0.87 |
Brick (4.0 in. thick) | 4.00 |
Concrete block (filled cores) | 1.93 |
Styrofoam (1.0 in. thick) | 5.0 |
Fiber glass batting (3.5 in. thick) | 10.90 |
Fiber glass batting (6.0 in. thick) | 18.80 |
Fiber glass board (1.0 in. thick) | 4.35 |
Cellulose fiber (1.0 in. thick) | 3.70 |
Flat glass (0.125 in. thick) | 0.89 |
Insulating glass (0.25-in. space) | 1.54 |
Vertical air space (3.5 in. thick) | 1.01 |
Stagnant layer of air | 0.17 |
Dry wall (0.50 in. thick) | 0.45 |
Sheathing (0.50 in. thick) | 1.32 |