Reconsider Prob. 3-126. Using EES (or other) software, investigate the effect of the initial pressure of refrigerant-134a on the volume of the tank. Let the initial pressure vary from 0.5 to 1.5 MPa. Plot the volume of the tank versus the initial pressure, and discuss the results.
EES Problem 3-126 is reconsidered. The effect of the initial pressure of refrigerant-134 on the volume of the tank is to be investigated as the initial pressure varies from 0.5 MPa to 1.5 MPa. The volume of the tank is to be plotted versus the initial pressure, and the results are to be discussed.
Analysis The problem is solved using EES, and the solution is given below
“Given Data” x_1=0.0 Vol_1=0.01[m^3] P_1=800 [kPa] T_2=20 [C] P_2=400 [kPa] “Solution” v_1=volume(R134a,P=P_1,x=x_1) Vol_1=m*v_1 v_2=volume(R134a,P=P_2,T=T_2) Vol_2=m*v_2 |
\mathrm{P} _1 [kPa] | \mathrm{Vol} _2 [m³] | m [kg] |
500 | 0.6727 | 12.41 |
600 | 0.6612 | 12.2 |
700 | 0.6507 | 12 |
800 | 0.641 | 11.82 |
900 | 0.6318 | 11.65 |
1000 | 0.6231 | 11.49 |
1100 | 0.6148 | 11.34 |
1200 | 0.6068 | 11.19 |
1300 | 0.599 | 11.05 |
1400 | 0.5914 | 10.91 |
1500 | 0.584 | 10.77 |