Question 3.127: Reconsider Prob. 3-126. Using EES (or other) software, inves......

Reconsider Prob. 3-126. Using EES (or other) software, investigate the effect of the initial pressure of refrigerant-134a on the volume of the tank. Let the initial pressure vary from 0.5 to 1.5 MPa. Plot the volume of the tank versus the initial pressure, and discuss the results.

The blue check mark means that this solution has been answered and checked by an expert. This guarantees that the final answer is accurate.
Learn more on how we answer questions.

EES Problem 3-126 is reconsidered. The effect of the initial pressure of refrigerant-134 on the volume of the tank is to be investigated as the initial pressure varies from 0.5 MPa to 1.5 MPa. The volume of the tank is to be plotted versus the initial pressure, and the results are to be discussed.

Analysis The problem is solved using EES, and the solution is given below

“Given Data”
x_1=0.0
Vol_1=0.01[m^3]
P_1=800 [kPa]
T_2=20 [C]
P_2=400 [kPa]
“Solution”
v_1=volume(R134a,P=P_1,x=x_1)
Vol_1=m*v_1
v_2=volume(R134a,P=P_2,T=T_2)
Vol_2=m*v_2
3.127
Loading more images...
\mathrm{P} _1 [kPa] \mathrm{Vol} _2 [m³] m [kg]
500 0.6727 12.41
600 0.6612 12.2
700 0.6507 12
800 0.641 11.82
900 0.6318 11.65
1000 0.6231 11.49
1100 0.6148 11.34
1200 0.6068 11.19
1300 0.599 11.05
1400 0.5914 10.91
1500 0.584 10.77