Question 4.39: A four-pole shunt generator with lap connected armature has ...

A four-pole shunt generator with lap connected armature has field and armature resistance of 50 \Omega  and 0.1 \Omega  respectively. The generator is supplying a load of 2.4 kW at 100 V . Calculate the armature current, current in each conductor and generated emf.

 

 

The Blue Check Mark means that this solution has been answered and checked by an expert. This guarantees that the final answer is accurate.
Learn more on how we answer questions.
\begin{array}{l}\text { Load current, } I_{L}=\frac{2.4 \times 1000}{100}=24 A\\\text { Shunt field current; } I_{s h}=\frac{V}{R_{s h}}=\frac{100}{50}=2 A\\\text { Armature current, } I_{a}=I_{L}+I_{s h}=24+2=26 A \\\text { Current in each conductor, } I_{c}=\frac{I_{a}}{A}=\frac{26}{6}= 4 . 3 3 A \\\begin{array}{l}\text { Generated emf, } E_{g}=V+I_{a} R_{a} \\=100+26 \times 0.1=102.6 V\end{array}\end{array}
4.39