Question 3.30: A small water tower has a cylindrical chamber 3 m in diamete...

A small water tower has a cylindrical chamber 3 m in diameter and 4 m tall. The bottom of the cylinder is 15 m above the ground. Water is pumped from an underground reservoir into the chamber. The surface of the reservoir is 5 m below the ground. Assume that the tower, reservoir and pipes are adiabatic, and that all water is at a uniform temperature, and a uniform density of 1000 g/cm³ .

A) When the water tower is completely empty, what is the minimum pump work required to move 1 kg of water into the tower?
B) When the water tower is almost full, what is the minimum pump work required to move 1 kg of water into the tower?
C) A home has a second floor faucet is 3 m above the ground. The ground in the area is level, and there is nothing powering the water except the force of gravity. When the faucet it turned on, what is the maximum velocity the water can have?
D) Suppose the water tower has these same dimensions, but is located on top of a hill. Re-do part C assuming the altitude of the water faucet is 5 m below the altitude at the top of the hill.

The Blue Check Mark means that this solution has been answered and checked by an expert. This guarantees that the final answer is accurate.
Learn more on how we answer questions.

A) Work = Force × Distance = Mass × Acceleration × Distance

Distance upward that the water is pumped is changing as time passes. Initially it is 20 meters: 5+15.

When there is 1 kg of water in the tower, the water level may be found by considering the density and dimensions of the water tower.

(1 \mathrm{~kg})\left(\frac{1000 \mathrm{~g}}{1 \mathrm{~kg}}\right)\left(\frac{1 \mathrm{~cm}^{3}}{1 \mathrm{~g}}\right)=1000 \mathrm{~cm}^{3}

Volume = Area of Base of Water Tower × Height =\frac{\pi}{4} Diameter² × Height

1000 \mathrm{~cm}^{3}=\frac{\pi}{4}(300 \mathrm{~cm})^{2} \times Height

This is the change in water level that accompanies adding 1 kg of water to the tower. It is so small that we will consider it negligible; the “distance” is 20 meters both at the beginning and at the end of the process of pumping 1 kg of water into the tower.

Work =1 \mathrm{~kg} \times 9.8 \frac{\mathrm{m}}{\mathrm{sec}^{2}} \times 20 \mathrm{~m}=\bf196 \mathbf{Nm}=\bf 196 \mathbf{~J}

B) The cylinder is 4 meters tall so the height is now 24 meters.

Work = Force × Distance = Mass × Acceleration × Distance
Work =1 \mathrm{~kg} \times 9.8 \frac{\mathrm{m}}{\mathrm{sec}^{2}} \times(20 \mathrm{~m}+4 \mathrm{~m})=\bf 235.2 \mathbf{Nm}=\bf 235.2 \mathbf{~J}

C)

Set up an energy balance. The control volume is as shown in the figure- it includes the faucet, the pipes leading to the faucet, and a portion of the water in the tower- but a portion of the tower, the top, is outside of the system. Thus water leaving the faucet is leaving the system, and the top layer of water is entering the system as the tower drains. This definition allows us to model the system as a steady state system. Of course, once all the water above the system has drained into the system, the system can no longer remain at steady state if water continues to flow out.

The maximum velocity occurs when the water tower is full. To find the absolute maximum velocity, we will assume the height of the water entering the system is 19 m off the ground- in other words, the “layer” of water that is above the system is very thin.

Assume steady state conditions yield maximum velocity, and frictionless piping.

\begin{aligned}\frac{\mathrm{d}}{\mathrm{dt}}\left\{\mathrm{M}\left(\widehat{\mathrm{U}}+\frac{\mathrm{v}^{2}}{2}+\mathrm{gh}\right)\right\}=\dot{\mathrm{m}}_{\mathrm{in}}\left(\widehat{\mathrm{H}}_{\mathrm{in}}+\frac{\mathrm{v}_{\text {in }}^{2}}{2}+\mathrm{gh}_{\mathrm{in}}\right)-\dot{\mathrm{m}}_{\mathrm{out}}\left(\widehat{\mathrm{H}}_{\mathrm{out}}+\frac{\mathrm{v}_{\text {out }}^{2}}{2}+\mathrm{gh}_{\mathrm{out}}\right)+\dot{\mathrm{W}}_{\mathrm{S}}+\dot{\mathrm{W}}_{\mathrm{EC}}+\dot{\mathrm{Q}}\end{aligned}

Cancelling Terms, use the height of the faucet at a baseline (h=0), this means h=16 at the top of the tower.

\begin{aligned}\mathrm{gh}_{\mathrm{in}} & =\left(\frac{\mathrm{v}_{\text {out }}^{2}}{2}\right) \\\mathrm{v}_{\text {out }} & =\sqrt{2\left(9.8 \frac{\mathrm{m}}{\mathrm{sec}^{2}}\right)(16 \mathrm{~m})} \\\mathrm{v}_{\text {out }} & =\bf17.7 \frac{\mathbf{m}}{\mathbf{sec}}\end{aligned}

D) The energy balance is identical to that in the previous problem, except here, the difference in height between the faucet and the top of the tower is now 24 meters (5+15+4).

\begin{aligned}& \frac{\mathrm{d}}{\mathrm{dt}}\left\{\mathrm{M}\left(\widehat{\mathrm{U}}+\frac{\mathrm{v}^{2}}{2}+\mathrm{gh}\right)\right\}=\dot{\mathrm{m}}_{\mathrm{in}}\left(\widehat{\mathrm{H}}_{\mathrm{in}}+\frac{\mathrm{v}_{\text {in }}^{2}}{2}+g h_{\mathrm{in}}\right)-\dot{\mathrm{m}}_{\text {out }}\left(\widehat{\mathrm{H}}_{\mathrm{out}}+\frac{\mathrm{v}_{\text {out }}^{2}}{2}+g h_{\mathrm{out}}\right)+\dot{\mathrm{W}}_{\mathrm{S}}+ \\& \dot{\mathrm{W}}_{\mathrm{EC}}+\dot{\mathrm{Q}} \\& \mathrm{gh}_{\mathrm{in}}=\left(\frac{\mathrm{v}_{\text {out }}^{2}}{2}\right) \\& \mathrm{v}_{\text {out }}=\sqrt{2\left(9.8 \frac{\mathrm{m}}{\sec ^{2}}\right)(24 \mathrm{~m})} \\& \mathrm{v}_{\text {out }}=\bf21.7 \frac{\mathbf{m}}{\bf sec }\end{aligned}

3.30