Question 10.2: Solve the problem in Example 10.1, if the ply thickness is e...

Solve the problem in Example 10.1 , if the ply thickness is experimentally found to be 0.4 mm for two rovings at a programmed bandwidth of 5 mm. What is the estimated fiber volume fraction?

The blue check mark means that this solution has been answered and checked by an expert. This guarantees that the final answer is accurate.
Learn more on how we answer questions.

The required programmed bandwidth is arrived at as follows:

b=5\times \frac{4}{2}\times \frac{0.4}{0.6}=6.67 \ mm

The estimated fiber volume fraction is

V_f=0.6\times \frac{5.13}{6.67}=0.46

Related Answered Questions