Question 4.13: The frequency of the rotor-induced EMF of 400 V, three-phase...
The frequency of the rotor-induced EMF of 400 V, three-phase, 50 Hz, six-pole induction motor is 2 Hz. Calculate the speed of the motor.
The blue check mark means that this solution has been answered and checked by an expert. This guarantees that the final answer is accurate.
Learn more on how we answer questions.
Learn more on how we answer questions.
N_{s} = \frac{120 f}{P} = \frac{120 × 50}{6} = 1000 rpm
Rotor frequency, f_{r} = Sf
or, 2 = S × 50
or, S = 0.04
Again, S = \frac{N_{s} – N_{r}}{N_{s}}
Substituting values 0.04 = \frac{ 1000 – N_{r}}{1000}
or, N_{r} = 960 rpm