Question 11.3: Determine the size of a galvanized iron pipe needed to trans...
Determine the size of a galvanized iron pipe needed to transmit water a distance of 180 m at 0.085 m ^{3}/s with a loss of head of 9 m. (Take kinematic viscosity of water ν = 1.14 × 10^{-6} m ^{2}/s, and the average surface roughness for galvanized iron = 0.15 mm).
Learn more on how we answer questions.
From (11.6b),
h_{f}=\frac{\Delta p^{*}}{\rho g}=f \frac{L}{D}\left(V^{2} / 2 g\right) (11.6b)
9=f \frac{180}{D}\left(\frac{0.085}{\pi D^{2} / 4}\right)^{2} \frac{1}{2 \times 9.81}
which gives D^{5}=0.012 f (11.8)
and \operatorname{Re}=\frac{0.085 D}{\left(\pi D^{2} / 4\right) \times 1.14 \times 10^{-6}}
=9.49 \times 10^{4} \frac{1}{D} (11.9)
First, a guess in f is made as 0.024.
Then from Eq. (11.8) D = 0.196 m
and from Eq. (11.9) \operatorname{Re}=4.84 \times 10^{5}
The relative roughness \varepsilon / D=\frac{0.15}{0.196} \times 10^{-3}=0.00076
With the values of Re and e/D, the updated value of f is found from Fig. 11.2 as 0.019. With this value of f as 0.019, a recalculation of D and Re from Eqs (11.8) and (11.9) gives D = 0.187 m, Re = 5.07 \times 10^{5}. e/D becomes (0.15/0.187) \times 10^{-3} = 0.0008. The new values of Re and ∈/D predict f = 0.0192 from Fig. 11.2. This value of f differs negligibly (by 1%) from the previous value of 0.019. Therefore the calculated diameter D = 0.187 m is accepted as the final value.