Question 12.19: A steam power plant operates on a theoretical reheat cycle. ...

A steam power plant operates on a theoretical reheat cycle. Steam at boiler at 150 bar, 550°C expands through the high pressure turbine. It is reheated at a constant pressure of 40 bar to 550°C and expands through the low pressure turbine to a condenser at 0.1 bar. Draw T-s and h-s diagrams. Find :

(i) Quality of steam at turbine exhaust ;

(ii) Cycle efficiency ;

(iii) Steam rate in kg/kWh.

The blue check mark means that this solution has been answered and checked by an expert. This guarantees that the final answer is accurate.
Learn more on how we answer questions.

Refer Figs. 12.27 and 12.28.

From Mollier diagram (h-s diagram) :

h_1=3450 kJ/kg ; h_2=3050 kJ/kg ; h_3=3560 kJ/kg ; h_4=2300 kJ/kg

h_{f_4} (from steam tables, at 0.1 bar) = 191.8 kJ/kg

(i) Quality of steam at turbine exhaust, x_4 :

x_4=0.88 (From Mollier diagram)

(ii) Cycle efficiency, \eta_{\text {cycle }} :

\eta_{\text {cycle }}=\frac{\left(h_1-h_2\right)+\left(h_3-h_4\right)}{\left(h_1-h_{f_4}\right)+\left(h_3-h_2\right)}

= \frac{(3450-3050)+(3560-2300)}{(3450-191.8)+(3560-3050)}=\frac{1660}{3768.2}= 0 . 4 4 0 5 or 44.05%.

(iii) Steam rate in kg/kWh :

Steam rate =\frac{3600}{\left(h_1-h_2\right)+\left(h_3-h_4\right)}=\frac{3600}{(3450-3050)+(3560-2300)}

= \frac{3600}{1660}=2.17 kg/kWh.

12.19