Question 3.29E: Reconsider Prob. 3.28E. Using EES (or other) software, deter......

Reconsider Prob. 3.28E. Using EES (or other) software, determine the missing properties of water. Repeat the solution for refrigerant-134a, refrigerant-22, and ammonia.

The blue check mark means that this solution has been answered and checked by an expert. This guarantees that the final answer is accurate.
Learn more on how we answer questions.

EES Problem 3.28E is reconsidered. The missing properties of water are to be determined using EES, and the solution is to be repeated for refrigerant-134a, refrigerant-22, and ammonia.

Analysis The problem is solved using EES, and the solution is given below.

“Given”

T[1]=300 [F]
u[1]=782 [Btu/lbm]
P[2]=40 [psia]
x[2]=0
T[3]=500 [F]
P[3]=120 [psia]
T[4]=400 [F]
P[4]=420 [psia]

“Analysis”

Fluid$=’steam_iapws’
P[1]=pressure(Fluid$, T=T[1], u=u[1])
x[1]=quality(Fluid$, T=T[1], u=u[1])
T[2]=temperature(Fluid$, P=P[2], x=x[2])
u[2]=intenergy(Fluid$, P=P[2], x=x[2])
u[3]=intenergy(Fluid$, P=P[3], T=T[3])
x[3]=quality(Fluid$, P=P[3], T=T[3])
u[4]=intenergy(Fluid$, P=P[4], T=T[4])
x[4]=quality(Fluid$, P=P[4], T=T[4])
“x = 100 for superheated vapor and x = -100 for compressed liquid”

Solution for steam

T, °F P, psia x u, Btu/lbm
300 67.028 0.6173 782
267.2 40 0 236
500 120 100 1174
400 400 -100 373.8