Holooly Plus Logo

Question 6.5: For the seven-story office building in Example 6.3, check th......

For the seven-story office building in Example 6.3, check the story drift limits in both the N-S and E-W directions. For illustration purposes, use the lateral deflections determined by the equivalent lateral force procedure.

Step-by-Step
The 'Blue Check Mark' means that this solution was answered by an expert.
Learn more on how do we answer questions.

1. Drift limits in N-S direction.

To check drift limits, the deflections determined by Eq. 12.8-15 must be used:

\delta_{x}=\frac{C_{d}{\delta}_{xe}}{I}

The maximum story displacements δ_{xe} in the N-S direction are summarized in Table 6.12. For special steel concentrically braced frames, the deflection amplification factor C_d is equal to 5 from Table 12.2-1.

A summary of the displacements at each floor level in the N-S direction is given in Table 6.13.

The interstory drifts Δ computed from the δ_{x} are also given in the table. The drift at story level x is determined by subtracting the design earthquake displacement at the bottom of the story from the design earthquake displacement at the top of the story:

\Delta=\delta_{x}-\delta_{x-1}

The design story drifts Δ shall not exceed the allowable story drift Δ_a given in Table 12.12-1. For Occupancy Category II and “all other structures,” Δ_a = 0.020h_{sx} where h_{sx} is the story height below level x.

For the 18-ft story height, Δ_a = 0.020×18×12 = 4.32 in. > 2.30 in.

For the 13-ft story heights, Δ_a = 0.020×13×12 = 3.12 in., which is greater than the values of Δ at floor levels 2 through 7.

Thus, drift limits are satisfied in the N-S direction.

2. Drift limits in the E-W direction.

The maximum story displacements δ_{xe} in the N-S direction are summarized in Table 6.12. For special steel moment frames, the deflection amplification factor C_d is equal to 5.5 from Table 12.2-1.

A summary of the displacements at each floor level in the E-W direction is given in Table 6.14. The interstory drifts Δ computed from the δ_{x} are also given in the table.

In accordance with 12.12.1.1, design story drifts Δ must not exceed Δ_a /ρ for seismic force-resisting systems comprised solely of moment frames in structures assigned to SDC D, E or F where ρ is the redundancy factor determined in accordance with 12.3.4.2.

Due to the Type 1b extreme torsional irregularity, ρ must be equal to 1.3. Therefore, for the 18-ft story height, Δ_a /ρ = 0.020×18×12/1.3 = 3.32 in. < 3.41 in.

For the 13-ft story heights, Δ_a /ρ = 0.020×13×12/1.3 = 2.40 in., which is less than the design drifts at stories 2 through 6.

Thus, drift limits are not satisfied in the N-S direction. Increasing member sizes may not be sufficient to reduce the design drift; including additional members in the seismic force-resisting system may be needed to control drift. This, in turn, may help reduce the torsional effects.

Table 6.13 Lateral Displacements and Story Drifts due to Seismic Forces in the N-S Direction

Story δ_{xe}
(in.)
δ_{x}
(in.)
Δ
(in.)
7 1.59 7.95 0.70
6 1.45 7.25 0.85
5 1.28 6.40 1.10
4 1.06 5.30 1.05
3 0.85 4.25 1.10
2 0.63 3.15 0.85
1 0.46 2.30 2.30

Table 6.14 Lateral Displacements and Story Drifts due to Seismic Forces in the E-W Direction

Story δ_{xe}
(in.)
δ_{x}
(in.)
Δ
(in.)
7 5.36 29.48 1.98
6 5.00 27.50 2.69
5 4.51 24.81 3.91
4 3.80 20.90 6.05
3 2.70 14.85 6.54
2 1.51 8.31 4.90
1 0.62 3.41 3.41

Table 6.12 Lateral Displacements and Story Drifts due to Seismic Forces

Story N-S Direction E-W Direction
(δ_\mathrm{xe})_1
(in.)
Δ_1
(in.)
(δ_\mathrm{xe})_2
(in.)
Δ_2
(in.)
Δ_\mathrm{avg}
(in.)
\frac{Δ_\mathrm{max}}{Δ_\mathrm{avg}} (δ_\mathrm{xe})_1
(in.)
Δ_1
(in.)
(δ_\mathrm{xe})_2
(in.)
Δ_2
(in.)
Δ_\mathrm{avg}
(in.)
\frac{Δ_\mathrm{max}}{Δ_\mathrm{avg}}
7 1.59 0.14 1.23 0.12 0.13 1.08 5.36 0.36 5.22 0.34 0.35 1.03
6 1.45 0.17 1.11 0.15 0.16 1.06 5.00 0.49 4.88 0.47 0.48 1.02
5 1.28 0.22 0.96 0.20 0.21 1.05 4.51 0.71 4.41 0.71 0.71 1.00
 4 1.06 0.21 0.76 0.19 0.20 1.05 3.80 1.10 3.70 1.06 1.08 1.02
 3 0.85 0.22 0.57 0.17 0.19 1.16 2.70 1.19 2.64 1.16 1.17 1.02
 2 0.63 0.17 0.40 0.22 0.19 1.16 1.51 0.89 1.48 0.87 0.88 1.01
 1 0.46 0.46 0.18 0.18 0.32 1.44 0.62 0.62 0.61 0.61 0.61 1.02

Related Answered Questions

Question: 6.9

Verified Answer:

• Step 1: Determine the seismic ground motion valu...
Question: 6.8

Verified Answer:

Use Flowchart 6.10 to determine the seismic force ...