Question 4.8: A four-pole dc generator has 1000 conductors. The flux per p...
A four-pole dc generator has 1000 conductors. The flux per pole is 25 mWb. Calculate the EMF induced when the armature is lap connected and run at 1500 rpm. At what speed the generator must be driven to produce the same EMF with the armature winding wave connected?
The blue check mark means that this solution has been answered and checked by an expert. This guarantees that the final answer is accurate.
Learn more on how we answer questions.
Learn more on how we answer questions.
Case I
P = 4, Z = 1000, Φ = 25 × 10^{−3} Wb
A = 4, N = 1500 rpm
Induced EMF, E = \frac{ΦZNP}{60 A} = \frac{25 × 10^{-3} × 1000 × 1500 × 4}{60 × 4}
For wave winding, A = 2 = 625 V
E to be the same,
625 =\frac{ΦZNP}{60 A} = \frac{25 × 10^{-3} × 1000 × N × 4}{60 × 2}
or, N = 750 rpm
Related Answered Questions
Question: 4.18
Verified Answer:
Total kVA = 1500
kVA per phase = \frac{1500...
Question: 4.17
Verified Answer:
Given line voltage = 6600 V
phase voltage ...
Question: 4.16
Verified Answer:
f = 50 Hz
P = 2, 4, 6, etc.
N_{s} = \frac{...
Question: 4.15
Verified Answer:
The synchronous generator is rotated at a synchron...
Question: 4.14
Verified Answer:
We know the synchronous speed of the rotating magn...
Question: 4.13
Verified Answer:
N_{s} = \frac{120 f}{P} = \frac{120 × 5...
Question: 4.9
Verified Answer:
Current flowing in each parallel path is the same ...
Question: 4.7
Verified Answer:
In a series motor the armature winding and the fie...
Question: 4.3
Verified Answer:
P = 6, A = P = 6 (because the armature winding is ...
Question: 4.2
Verified Answer:
P = 4, A = 2 (because the armature winding is wa...