Question 4.2: A four-pole dc generator having wave wound armature winding ...
A four-pole dc generator having wave wound armature winding has 51 slots, each slot containing 20 conductors. Calculate the voltage generated in the armature when driven at 1500 rpm. Assume flux per pole to be 0.5 mWb.
The blue check mark means that this solution has been answered and checked by an expert. This guarantees that the final answer is accurate.
Learn more on how we answer questions.
Learn more on how we answer questions.
P = 4, A = 2 (because the armature winding is wave wound)
N = 1500 rpm
Total number of armature conductors,
Z = 20 × 51
= 1020
Equation for induced EMF, E= \frac{ΦZNP}{60A} V
Substituting values E= \frac{0.5 × 10^{-3} × 1020 × 1500 × 4}{60 × 2}
= 255 V
Related Answered Questions
Question: 4.18
Verified Answer:
Total kVA = 1500
kVA per phase = \frac{1500...
Question: 4.17
Verified Answer:
Given line voltage = 6600 V
phase voltage ...
Question: 4.16
Verified Answer:
f = 50 Hz
P = 2, 4, 6, etc.
N_{s} = \frac{...
Question: 4.15
Verified Answer:
The synchronous generator is rotated at a synchron...
Question: 4.14
Verified Answer:
We know the synchronous speed of the rotating magn...
Question: 4.13
Verified Answer:
N_{s} = \frac{120 f}{P} = \frac{120 × 5...
Question: 4.9
Verified Answer:
Current flowing in each parallel path is the same ...
Question: 4.8
Verified Answer:
Case I
P = 4, Z = 1000, Φ = 25 × 10^{−3} W...
Question: 4.7
Verified Answer:
In a series motor the armature winding and the fie...
Question: 4.3
Verified Answer:
P = 6, A = P = 6 (because the armature winding is ...