Question 12.15: Calculate the second harmonic distortion if an output wavefo...

Calculate the second harmonic distortion if an output waveform displayed on an oscilloscope provides the following measurements:

a. V_{C E_{\text {min }}}=1 V , V_{C E_{\text {max }}}=22 V , V_{C E_{Q}}=12 V.

 

b. V_{C E_{\min }}=4 V , V_{C E_{\max }}=20 V , V_{C E_{Q}}=12 V

 

The blue check mark means that this solution has been answered and checked by an expert. This guarantees that the final answer is accurate.
Learn more on how we answer questions.

Using Eq. (12.34),

D_{2}=\left|\frac{\frac{1}{2}\left(V_{C E_{\max }}+V_{C E_{\min }}\right)-V_{C E_{Q}}}{V_{C E_{\max }}-V_{C E_{\min }}}\right| \times 100 \%                                (12.34)

we get

a.  D_{2}=\left|\frac{\frac{1}{2}(22 V +1 V )-12 V }{22 V -1 V }\right| \times 100 \%= 2 . 3 8 \%

 

b.    D_{2}=\left|\frac{\frac{1}{2}(20 V +4 V )-12 V }{20 V -4 V }\right| \times 100 \%= 0 \%                              (no distortion)