Question 10.7: Outline the procedures for determining the carbon requiremen...
Outline the procedures for determining the carbon requirement of a canister system (Fig. 2).

Learn more on how we answer questions.
The carbon requirement for a canister system can be estimated using
C_{req} = M_{HAP} θ_{ad}/W_{c} (11)
C_{req} = ــــــــــــــــــــــــــــــــــــــ lb of carbon
If the HAP inlet loading (M_{HAP}) is not given, it can be determined
M_{HAP} = 6.0 \times 10^{−5} (HAP_{e})(Q_{e})(D_{HAP}) (4)
M_{HAP} = ــــــــــــــــــــــــــــــــــــــ lb of HAP/h
To determine the required canister number (RCN), the C_{req} is divided by the amount of carbon contained in a single canister and rounded up to the next whole number. Typically, each canister contains 150 lb of carbon.
RCN = C_{req}/(150 lb carbon/canister)
RCN = ــــــــــــــــــــــــــــــــــــــ