Holooly Plus Logo

Question 10.2: A test on the main winding of a 1 kW, 4-pole. 2 15 V, 50 Hz,...

A test on the main winding of a 1 kW, 4-pole. 2 15 V, 50 Hz, single-phase induction motor gave the following results:

No-load test

Rotor-blocked test

V_{0} = 215 V

V_{SC} = 85 A

I0 = 3.9 A

I_{SC} = 9.80 A

P_{0} = 185 W

P_{SC} = 390 W

R_{1} = 1.6 \Omega

Given:

(a) Calculate the parameters of the circuit model assuming that the magnetizing reactance hangs at the input terminals of the model.

(b) Determine the line current power factor, shaft torque and efficiency of the motor at a speed of 1440 rpm

The "Step-by-Step Explanation" refers to a detailed and sequential breakdown of the solution or reasoning behind the answer. This comprehensive explanation walks through each step of the answer, offering you clarity and understanding.
Our explanations are based on the best information we have, but they may not always be right or fit every situation.
The Blue Check Mark means that this solution has been answered and checked by an expert. This guarantees that the final answer is accurate.
Learn more on how we answer questions.