Finding the Performance Parameters of a Flyback Converter
The average (or dc) output voltage of the flyback circuit in Figure 13.1a is V_o = 24 V at a resistive load of R = 0.8 Ω. The duty-cycle ratio is k = 50\% and the switching frequency is f = 1 kHz. The on-state voltage drops of transistors and diodes are V_t = 1.2 V and V_d = 0.7 V, respectively. The turns ratio of the transformer is a = N_s/N_p = 0.25. Determine (a) the average input current I_s, (b) the efficiency η, (c) the average transistor current I_A, (d) the peak transistor current I_p, (e) the rms transistor current I_R, (f) the open-circuit transistor voltage V_{oc}, and (g) the primary magnetizing inductor L_p. Neglect the losses in the transformer and the ripple current of the load.