Question 6.T-Y-S.H: Two insulation thickness alternatives have been proposed for...

Two insulation thickness alternatives have been proposed for a process steam line subject to severe weather conditions. One alternative must be selected. Estimated savings in heat loss and installation cost are given below.

Thickness Installed Cost Annual Savings Life
2 cm $20,000 $5,000 4 years
5 cm $40,000 $7,500 6 years

Which thickness would you recommend for a MARR =15 \% per year and negligible market (salvage) values? The study period is 12 years. (6.5)

The Blue Check Mark means that this solution has been answered and checked by an expert. This guarantees that the final answer is accurate.
Learn more on how we answer questions.

\operatorname{AW}_{2 \mathrm{~cm}}(15 \%)=-\$ 20,000(A / P, 15 \%, 4)+\$ 5,000=-\$ 2,006 per year

\mathrm{AW}_{5 \mathrm{~cm}}(15 \%)=-\$ 40,000(A / P, 15 \%, 6)+\$ 7,500=-\$ 3,068 per year

Therefore, the 2 \mathrm{~cm} thickness should be recommended.