Water at 20^{\circ} C flows in a 0.7-m-diameter horizontal pipe. An orifice meter with a 0.3-m diameter is mounted in the flanged pipe just upstream of point 2 as illustrated in Figure EP 5.16 in order to measure the flowrate in the pipe. A pressure tap, p_{1} is installed at point 1, where the full pipe flow occurs just upstream of the orifice, and a pressure tap, p_{2} is installed at point 2, where the vena contracta occurs just downstream of the orifice. The pressure at point 1, p_{1} is measured to be 3× 10^{5} N/m^{2} p_{1} [/latex] , and the pressure at point 2, p_{2} is measured to be 2.5 × 10^{5} N/m^{2} . The orifice discharge coefficient, C_{o} is 0.6. (a) Determine the ideal flowrate. (b) Determine the actual flowrate.