Search ...
Results
Subscribe
Step-by-Step Solutions
University Majors
Support Hub
Legal & Support Articles
Contact Us
Login
Share
Search ...
Results
Subscribe
Step-by-Step Solutions
University Majors
Support Hub
Legal & Support Articles
Contact Us
Login
Share
Electric Circuits
Principles of Electric Circuits Conventional Current
355 SOLVED PROBLEMS
Question: 9.10
A series RC circuit has a resistance of 1.0 MΩ and a capacitance of 4.7 μF. What is the time constant? ...
Verified Answer:
\tau
= RC = (1.0 × 10
^{6}[/l...
Question: 21.8
In a certain Δ-connected balanced load, the line voltages are 250 V and the impedances are 50∠30° Ω. Determine the total load power. ...
Verified Answer:
In a Δ-connected system,
V_{Z}=V_{L}[/latex...
Question: 21.7
Determine the magnitude of the load currents and the line currents in Figure 21–28. ...
Verified Answer:
V_{Z a}=V_{Z b}=V_{Z c}=240 V
The ...
Question: 21.6
Determine the currents and voltages in the balanced load and the magnitude of the line voltages in Figure 21–26. ...
Verified Answer:
The load currents equal the specified line current...
Question: 21.5
Determine the load voltages and load currents in Figure 21–23, and show their relationship in a phasor diagram. ...
Verified Answer:
Using
V_{L}=\sqrt{3} V_{\theta}
(Eq...
Question: 21.4
In the Y-Y system of Figure 21–21, determine the following: (a) Each load current (b) Each line current (c) Each phase current (d) Neutral current (e) Each load voltage ...
Verified Answer:
This system has a balanced load
Z _{a}= Z _...
Question: 21.3
The three-phase Δ-connected generator represented in Figure 21–17 is driving a balanced load such that each phase current is 10 A in magnitude. When Iθa = 10∠30° A, determine the following: (a) The polar expressions for the other phase currents (b) The polar expressions for each of the line ...
Verified Answer:
(a) The phase currents are separated by 120°; ther...
Question: 21.2
The instantaneous position of a certain Y-connected ac generator is shown in Figure 21–12. If each phase voltage has a magnitude of 120 V rms, determine the magnitude of each line voltage, and draw the phasor diagram. ...
Verified Answer:
The magnitude of each line voltage is
V_{L}...
Question: 21.1
Compare the total copper cross sections in terms of current-carrying capacity for single-phase and three-phase 120 V systems with effective load resistances of 12 Ω. ...
Verified Answer:
Single-phase system : The load current is
I...
Question: 20.10
Determine the output voltage waveform for the RL differentiator in Figure 20–45. ...
Verified Answer:
First, calculate the time constant.
\tau=\f...
Loading...
Load More Questions