Holooly Plus Logo

Question 10.4: A reboiler is required to supply 15,000 lb/h of vapor to a d...

A reboiler is required to supply 15,000 lb/h of vapor to a distillation column that separates cyclohexane as the bottom product. The heating medium will be steam at a design pressure of 18 psia. The temperature and pressure below the bottom tray in the column are 182º F and 16 psia. Physical property data for cyclohexane at these conditions are given in the following table:

Property Liquid Vapor
ρ (lbm/ft3) 45 0.2
μ (cp) 0.4 0.0086
C_ {p} (Btu/lbm . ºF) 0.45
k (Btu/h . ft .ºF) 0.086
σ (lbf/ft) 0.00124
λ (Btu/lbm) 154
Pr 5.063

The vapor pressure of cyclohexane is given by the following equation [17], where P_ {sat } ∝ torr and T ∝ K:

P_{\text {sat }}=\exp \left[15.7527-\frac{2766.63}{T-50.50}\right]

The critical pressure of cyclohexane is 590.5 psia.
The feed line to the reboiler will consist of 100 equivalent feet of 6-in. schedule 40 pipe, and the return line will consist of 50 equivalent feet of 10-in. schedule 40 pipe. Design a recirculating vertical thermosyphon reboiler for this service.

The "Step-by-Step Explanation" refers to a detailed and sequential breakdown of the solution or reasoning behind the answer. This comprehensive explanation walks through each step of the answer, offering you clarity and understanding.
Our explanations are based on the best information we have, but they may not always be right or fit every situation.
The blue check mark means that this solution has been answered and checked by an expert. This guarantees that the final answer is accurate.
Learn more on how we answer questions.
Already have an account?

Related Answered Questions

Question: 10.2

Verified Answer:

(a) Make initial specifications. (i) Fluid placeme...
Question: 10.9

Verified Answer:

Starting from the 15.25-in. unit rated in the prev...