Heat Transfer
Process Heat Transfer. Principles, Applications and Rules of Thumb
87 SOLVED PROBLEMS
Question: 11.10
Use Xist to obtain a final design for the C4–C5 condenser of Example 11.9. ...
Verified Answer:
Using Xist to rate the 39-in. J-shell condenser in...
Question: 11.11
100,000 kg/hr of propane are condensed on the shell-side of a horizontal TEMA E shell (type AEU). The inlet vapor temperature is 70.79 ºC and the outlet condensate temperature is 48.9 ºC. There is about 20°C of desuperheating and less than 1 ºC of subcooling. As with most industrial propane, small ...
Verified Answer:
The overall attributes of a design with single seg...
Question: 10.2
96,000 lb/h of a distillation bottoms having the following composition will be partially vaporized in a reboiler: ...
Verified Answer:
(a) Make initial specifications. (i) Fluid placeme...
Question: 11.6
180,000 lb/h of a saturated vapor consisting of 30 mole percent n-butane and 70 mole percent n-pentane are to be condensed at a pressure of 75 psia. The condensing range at feed conditions is from 183.5ºF to 168ºF, and the enthalpy difference between saturated vapor and saturated liquid is ...
Verified Answer:
Make initial specifications. (i) Fluid placement A...
Question: 9.3
Estimate the critical heat flux for the conditions of Example 9.1 using the following methods:(a) The Zuber equation.(b) The Zuber-type equation for a horizontal cylinder.(c) The Mostinski correlation. ...
Verified Answer:
(a) The following data are obtained from Example 9...
Question: 10.4
A reboiler is required to supply 15,000 lb/h of vapor to a distillation column that separates cyclohexane as the bottom product. The heating medium will be steam at a design pressure of 18 psia. The temperature and pressure below the bottom tray in the column are 182º F and 16 psia. Physical ...
Verified Answer:
(a) Make initial specifications. (i) Fluid placeme...
Question: 5.4
Use HEXTRAN to design a shell-and-tube heat exchanger for the kerosene/crude-oil service of Example 5.1, and compare the resulting unit with the one designed previously by hand. ...
Verified Answer:
The STE module in HEXTRAN is configured in design ...
Question: 10.7
Use Xist to rate the kettle reboiler designed in Example 10.2, and compare the results with those obtained previously by other methods. ...
Verified Answer:
Data from Example 10.2 are entered on the appropri...
Question: 9.5
The return line from a thermosyphon reboiler consists of 10-in. schedule 40 pipe with an ID of 10.02 in. (0.835 ft). The total mass flow rate in the line is 300,000 lbm/h, of which 60,000 lbm/h (20%) is vapor and 240,000 lbm/h is liquid. Physical properties of the vapor and liquid fractions are ...
Verified Answer:
(a) The friction loss for the liquid fraction flow...
Question: 10.8
Use Xist to rate the initial configuration for the vertical thermosyphon reboiler of Example 10.4 and compare the results with those obtained previously by hand. ...
Verified Answer:
Data from Example 10.4 are entered on the Xist inp...