Question 2.13: A thermocouple with test junction at t°C on gas thermometer ...
A thermocouple with test junction at t°C on gas thermometer scale and reference junction at ice point gives the e.m.f. as
e=0.20 t-5 \times 10^{-4} t^2 mV.
The millivoltmeter is calibrated at ice and steam points. What will be the reading on this thermometer where the gas thermometer reads 70°C ?
The "Step-by-Step Explanation" refers to a detailed and sequential breakdown of the solution or reasoning behind the answer. This comprehensive explanation walks through each step of the answer, offering you clarity and understanding.
Our explanations are based on the best information we have, but they may not always be right or fit every situation.
Our explanations are based on the best information we have, but they may not always be right or fit every situation.
The blue check mark means that this solution has been answered and checked by an expert. This guarantees that the final answer is accurate.
Learn more on how we answer questions.
Learn more on how we answer questions.
Related Answered Questions
Question: 2.9
Verified Answer:
Refer Fig. 2.28.
Let m = mass of the piston, kg.
p...
Question: 2.22
Verified Answer:
Refer Fig. 2.39.
Mass of fluid, m = 1 kg
p_...
Question: 2.15
Verified Answer:
Refer Fig. 2.34. The firm line B_1 ...
Question: 2.21
Verified Answer:
Refer Fig. 2.38.
p_1=3 \text { bar }=3 \tim...
Question: 2.20
Verified Answer:
Amount of work supplied to a closed system = 150 k...
Question: 2.19
Verified Answer:
Initial pressure, p_1=1.5 bar
Final...
Question: 2.18
Verified Answer:
Area of diesel engine piston
= 45 cm ^2=45 ...
Question: 2.17
Verified Answer:
Refer Fig. 2.36.
Work done by the stirring device ...
Question: 2.16
Verified Answer:
Fig. 2.35 shows the initial and final condition of...
Question: 2.14
Verified Answer:
(i) \int p d V :